Real time heart rate estimation from severely corrupted PPG signal by motion artifact

This thesis report is submitted in partial fulfilment of the requirements for the degree of Bachelor of Science in Electrical and Electronic Engineering, 2017.

Manylion Llyfryddiaeth
Prif Awduron: Imtiaz, Mohammad Masuk, Tina, Tahmina Ahmed
Awduron Eraill: Chowdhury, Sayeed Shafayet
Fformat: Traethawd Ymchwil
Iaith:English
Cyhoeddwyd: BRAC University 2017
Pynciau:
Mynediad Ar-lein:http://hdl.handle.net/10361/8610
id 10361-8610
record_format dspace
spelling 10361-86102019-09-30T02:57:18Z Real time heart rate estimation from severely corrupted PPG signal by motion artifact Imtiaz, Mohammad Masuk Tina, Tahmina Ahmed Chowdhury, Sayeed Shafayet Department of Electrical and Electronic Engineering, BRAC University PPG Heart rate Photoplethysmography Motion artifact This thesis report is submitted in partial fulfilment of the requirements for the degree of Bachelor of Science in Electrical and Electronic Engineering, 2017. Cataloged from PDF version of thesis. Includes bibliographical references (page 51). Heart rate is a very important cardio logical data. It is considered to be one of the most important vital sign of a human body. Real time heart rate monitoring provides a great advantage over many aspects. PPG is a low cost and simple method to measure volumetric changes in blood vessel. It consist of vital physiological data along with heart rate. But PPG data gets extremely corrupted with motion artifacts, thus it is difficult to achieve clean PPG data which has been distorted by all sorts of motion. Our method of removing motion artifacts and estimating heart rate included 3 major parts. Adaptive noise cancellation based of four different motion artifact source. Peak tracking method from the four different heart rate estimate for every real time window. Last step was a systematic verification method so that the abrupt changes in PPG does not lead the estimation of heart rate in the wrong direction. Our method of estimating heart rate had an absolute error of about 1.73 beats per min, which is a satisfactory result. This method provides a very robust system in measuring heart rate and also promises result with unbelievingly high accuracy. It can be concluded that this method provides high level of accuracy which can be implemented in today’s high tech health monitoring devices. Mohammad Masuk Imtiaz Tahmina Ahmed Tina B. Electrical and Electronic Engineering  2017-12-18T05:19:06Z 2017-12-18T05:19:06Z 2017 2017-08 Thesis ID 13121152 ID 13121021 http://hdl.handle.net/10361/8610 en BRAC University thesis is protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. 60 pages application/pdf BRAC University
institution Brac University
collection Institutional Repository
language English
topic PPG
Heart rate
Photoplethysmography
Motion artifact
spellingShingle PPG
Heart rate
Photoplethysmography
Motion artifact
Imtiaz, Mohammad Masuk
Tina, Tahmina Ahmed
Real time heart rate estimation from severely corrupted PPG signal by motion artifact
description This thesis report is submitted in partial fulfilment of the requirements for the degree of Bachelor of Science in Electrical and Electronic Engineering, 2017.
author2 Chowdhury, Sayeed Shafayet
author_facet Chowdhury, Sayeed Shafayet
Imtiaz, Mohammad Masuk
Tina, Tahmina Ahmed
format Thesis
author Imtiaz, Mohammad Masuk
Tina, Tahmina Ahmed
author_sort Imtiaz, Mohammad Masuk
title Real time heart rate estimation from severely corrupted PPG signal by motion artifact
title_short Real time heart rate estimation from severely corrupted PPG signal by motion artifact
title_full Real time heart rate estimation from severely corrupted PPG signal by motion artifact
title_fullStr Real time heart rate estimation from severely corrupted PPG signal by motion artifact
title_full_unstemmed Real time heart rate estimation from severely corrupted PPG signal by motion artifact
title_sort real time heart rate estimation from severely corrupted ppg signal by motion artifact
publisher BRAC University
publishDate 2017
url http://hdl.handle.net/10361/8610
work_keys_str_mv AT imtiazmohammadmasuk realtimeheartrateestimationfromseverelycorruptedppgsignalbymotionartifact
AT tinatahminaahmed realtimeheartrateestimationfromseverelycorruptedppgsignalbymotionartifact
_version_ 1814309619406733312