Anesthesia monitoring device development

This thesis report is submitted in partial fulfillment of the requirements for the degree of Bachelor of Science in Computer Science and Engineering, 2005.

Bibliografiske detaljer
Main Authors: Rahman, Tasneem, Suchi, Khadija Akhter
Andre forfattere: Rabbani, Khondkar Siddique-e
Format: Thesis
Sprog:English
Udgivet: Computer Science and Engineering, BRAC University 2011
Fag:
Online adgang:http://hdl.handle.net/10361/738
id 10361-738
record_format dspace
spelling 10361-7382022-01-26T10:21:48Z Anesthesia monitoring device development Rahman, Tasneem Suchi, Khadija Akhter Rabbani, Khondkar Siddique-e Department of Computer Science and Engineering, BRAC University Computer science and engineering This thesis report is submitted in partial fulfillment of the requirements for the degree of Bachelor of Science in Computer Science and Engineering, 2005. Cataloged from PDF version of thesis report. Includes bibliographical references (page 49). This thesis explores the problems of anesthesia during any surgical operation for the patients. There are few aspects of this work: determine the specified problems for proper anesthesia and necessity to monitor the depth of anesthesia level. Study of the existing methods of monitoring the anesthesia level further provides the opportunity to design an efficient and compatible anesthesia monitoring device. Work with electroencephalogram (EEG) which is the most important method for anesthesia level detection. Aspects presented here widen future implementation and tests of the proposed models. Tasneem Rahman Khadija Akhter Suchi B. Computer Science and Engineering 2011-01-26T06:55:15Z 2011-01-26T06:55:15Z 2009 2009-08 Thesis ID 05310008 ID 05301008 http://hdl.handle.net/10361/738 en BRAC University thesis are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. 49 pages application/pdf Computer Science and Engineering, BRAC University
institution Brac University
collection Institutional Repository
language English
topic Computer science and engineering
spellingShingle Computer science and engineering
Rahman, Tasneem
Suchi, Khadija Akhter
Anesthesia monitoring device development
description This thesis report is submitted in partial fulfillment of the requirements for the degree of Bachelor of Science in Computer Science and Engineering, 2005.
author2 Rabbani, Khondkar Siddique-e
author_facet Rabbani, Khondkar Siddique-e
Rahman, Tasneem
Suchi, Khadija Akhter
format Thesis
author Rahman, Tasneem
Suchi, Khadija Akhter
author_sort Rahman, Tasneem
title Anesthesia monitoring device development
title_short Anesthesia monitoring device development
title_full Anesthesia monitoring device development
title_fullStr Anesthesia monitoring device development
title_full_unstemmed Anesthesia monitoring device development
title_sort anesthesia monitoring device development
publisher Computer Science and Engineering, BRAC University
publishDate 2011
url http://hdl.handle.net/10361/738
work_keys_str_mv AT rahmantasneem anesthesiamonitoringdevicedevelopment
AT suchikhadijaakhter anesthesiamonitoringdevicedevelopment
_version_ 1814309471765135360