FPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting system

This thesis report is submitted in partial fulfillment of the requirements for the degree of Master of Electrical and Electronic Engineering, 2015.

Détails bibliographiques
Auteur principal: Begum, Mohaimina
Autres auteurs: Rahman, Dr. Md. Mosaddequr
Format: Thèse
Langue:English
Publié: BRAC University 2016
Sujets:
Accès en ligne:http://hdl.handle.net/10361/4824
id 10361-4824
record_format dspace
spelling 10361-48242019-09-30T04:18:03Z FPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting system Begum, Mohaimina Rahman, Dr. Md. Mosaddequr Department of Electrical and Electronic Engineering, BRAC University Electrical and electronic engineering Single Channel Analyzer (SCA) This thesis report is submitted in partial fulfillment of the requirements for the degree of Master of Electrical and Electronic Engineering, 2015. Cataloged from PDF version of thesis report. Includes bibliographical references (page 47-48). Hardware configurable Single Channel Analyzer (SCA) is designed and developed to improve the performance and flexibility of the system compared with traditional approaches. In this work, a new technique has been introduced for changing the window between the Upper Level Detection (ULD) and the lower Level Detection (LLD) for SCA by a simple change in software, without any hardware modification. To check this technique, electric pulse generated from the detector conditioned by a preamplifier is fed to ADC through a processing circuit. When the ADC output value is higher than the LLD and lower than the ULD, then counter will count those values over a period of one minute and store the counting value in a register. Finally the stored counting values are given to LCD through other necessary circuits. In addition, maximum peak value, counts per minute and total counting value are also displayed on LCD. Associate firmware has been developed by Xilinx ISE Design suite 9.2 using VHDL code and tested on Xilinx Spartan 3E Starter board. This developed system may be effectively used for radiation monitoring of human body as well as environment. Mohaimina Begum M. Electrical and Electronic Engineering 2016-01-14T15:17:41Z 2016-01-14T15:17:41Z 2015 2015-10 Thesis ID 10371003 http://hdl.handle.net/10361/4824 en BRAC University Internship reports are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. 93 pages application/pdf BRAC University
institution Brac University
collection Institutional Repository
language English
topic Electrical and electronic engineering
Single Channel Analyzer (SCA)
spellingShingle Electrical and electronic engineering
Single Channel Analyzer (SCA)
Begum, Mohaimina
FPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting system
description This thesis report is submitted in partial fulfillment of the requirements for the degree of Master of Electrical and Electronic Engineering, 2015.
author2 Rahman, Dr. Md. Mosaddequr
author_facet Rahman, Dr. Md. Mosaddequr
Begum, Mohaimina
format Thesis
author Begum, Mohaimina
author_sort Begum, Mohaimina
title FPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting system
title_short FPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting system
title_full FPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting system
title_fullStr FPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting system
title_full_unstemmed FPGA based Single Channel Analyzer (SCA) used for nuclear radiation counting system
title_sort fpga based single channel analyzer (sca) used for nuclear radiation counting system
publisher BRAC University
publishDate 2016
url http://hdl.handle.net/10361/4824
work_keys_str_mv AT begummohaimina fpgabasedsinglechannelanalyzerscausedfornuclearradiationcountingsystem
_version_ 1814307032389386240