An analytical assessment of GPL kit for field level detection of arsenic in water
An attempt was taken to evaluate the suitability of GPL kit for field level detection of arsenic in water. The sources of variation in results of tests for arsenic determined by GPL kit seemed to be use of different sets of apparatus, reagents and person to person handling of the apparatus. Varia...
मुख्य लेखक: | |
---|---|
स्वरूप: | Research report |
भाषा: | English |
प्रकाशित: |
BRAC Research and Evaluation Division (RED)
2020
|
विषय: | |
ऑनलाइन पहुंच: | http://hdl.handle.net/10361/13415 |
id |
10361-13415 |
---|---|
record_format |
dspace |
spelling |
10361-134152020-01-07T21:01:24Z An analytical assessment of GPL kit for field level detection of arsenic in water Hossain, Md. Zabed BRAC Arsenic GPL kit Tubewell water Water--Purification--Arsenic removal Arsenic--Environmental aspects Water--Pollution Arsenic--Toxicology An attempt was taken to evaluate the suitability of GPL kit for field level detection of arsenic in water. The sources of variation in results of tests for arsenic determined by GPL kit seemed to be use of different sets of apparatus, reagents and person to person handling of the apparatus. Variation in results of tests due to use of different sets of the GPL kit was more prominent (Standard deviation 76.524) than that of the reagents used and person to person handling (Standard deviation 40). Among the three sources of variation person to person handling of the kits bad the least effect on the test results. Results given by GPL and NIPSOM kits did not differ qualitatively although differed quantitatively. 2020-01-07T09:14:17Z 2020-01-07T09:14:17Z 1999-07 Research report Hossain, M. Z. (1999, July). An analytical assessment of GPL kit for field level detection of arsenic in water. Research Reports (1999): Social Studies, Vol – XXIV, 101–115. http://hdl.handle.net/10361/13415 en application/pdf BRAC Research and Evaluation Division (RED) |
institution |
Brac University |
collection |
Institutional Repository |
language |
English |
topic |
BRAC Arsenic GPL kit Tubewell water Water--Purification--Arsenic removal Arsenic--Environmental aspects Water--Pollution Arsenic--Toxicology |
spellingShingle |
BRAC Arsenic GPL kit Tubewell water Water--Purification--Arsenic removal Arsenic--Environmental aspects Water--Pollution Arsenic--Toxicology Hossain, Md. Zabed An analytical assessment of GPL kit for field level detection of arsenic in water |
description |
An attempt was taken to evaluate the suitability of GPL kit for field level detection of
arsenic in water. The sources of variation in results of tests for arsenic determined by GPL
kit seemed to be use of different sets of apparatus, reagents and person to person handling
of the apparatus. Variation in results of tests due to use of different sets of the GPL kit was
more prominent (Standard deviation 76.524) than that of the reagents used and person to
person handling (Standard deviation 40). Among the three sources of variation person to
person handling of the kits bad the least effect on the test results. Results given by GPL
and NIPSOM kits did not differ qualitatively although differed quantitatively. |
format |
Research report |
author |
Hossain, Md. Zabed |
author_facet |
Hossain, Md. Zabed |
author_sort |
Hossain, Md. Zabed |
title |
An analytical assessment of GPL kit for field level detection of arsenic in water |
title_short |
An analytical assessment of GPL kit for field level detection of arsenic in water |
title_full |
An analytical assessment of GPL kit for field level detection of arsenic in water |
title_fullStr |
An analytical assessment of GPL kit for field level detection of arsenic in water |
title_full_unstemmed |
An analytical assessment of GPL kit for field level detection of arsenic in water |
title_sort |
analytical assessment of gpl kit for field level detection of arsenic in water |
publisher |
BRAC Research and Evaluation Division (RED) |
publishDate |
2020 |
url |
http://hdl.handle.net/10361/13415 |
work_keys_str_mv |
AT hossainmdzabed ananalyticalassessmentofgplkitforfieldleveldetectionofarsenicinwater AT hossainmdzabed analyticalassessmentofgplkitforfieldleveldetectionofarsenicinwater |
_version_ |
1814307194114408448 |