An analytical assessment of GPL kit for field level detection of arsenic in water

An attempt was taken to evaluate the suitability of GPL kit for field level detection of arsenic in water. The sources of variation in results of tests for arsenic determined by GPL kit seemed to be use of different sets of apparatus, reagents and person to person handling of the apparatus. Varia...

पूर्ण विवरण

ग्रंथसूची विवरण
मुख्य लेखक: Hossain, Md. Zabed
स्वरूप: Research report
भाषा:English
प्रकाशित: BRAC Research and Evaluation Division (RED) 2020
विषय:
ऑनलाइन पहुंच:http://hdl.handle.net/10361/13415
id 10361-13415
record_format dspace
spelling 10361-134152020-01-07T21:01:24Z An analytical assessment of GPL kit for field level detection of arsenic in water Hossain, Md. Zabed BRAC Arsenic GPL kit Tubewell water Water--Purification--Arsenic removal Arsenic--Environmental aspects Water--Pollution Arsenic--Toxicology An attempt was taken to evaluate the suitability of GPL kit for field level detection of arsenic in water. The sources of variation in results of tests for arsenic determined by GPL kit seemed to be use of different sets of apparatus, reagents and person to person handling of the apparatus. Variation in results of tests due to use of different sets of the GPL kit was more prominent (Standard deviation 76.524) than that of the reagents used and person to person handling (Standard deviation 40). Among the three sources of variation person to person handling of the kits bad the least effect on the test results. Results given by GPL and NIPSOM kits did not differ qualitatively although differed quantitatively. 2020-01-07T09:14:17Z 2020-01-07T09:14:17Z 1999-07 Research report Hossain, M. Z. (1999, July). An analytical assessment of GPL kit for field level detection of arsenic in water. Research Reports (1999): Social Studies, Vol – XXIV, 101–115. http://hdl.handle.net/10361/13415 en application/pdf BRAC Research and Evaluation Division (RED)
institution Brac University
collection Institutional Repository
language English
topic BRAC
Arsenic
GPL kit
Tubewell water
Water--Purification--Arsenic removal
Arsenic--Environmental aspects
Water--Pollution
Arsenic--Toxicology
spellingShingle BRAC
Arsenic
GPL kit
Tubewell water
Water--Purification--Arsenic removal
Arsenic--Environmental aspects
Water--Pollution
Arsenic--Toxicology
Hossain, Md. Zabed
An analytical assessment of GPL kit for field level detection of arsenic in water
description An attempt was taken to evaluate the suitability of GPL kit for field level detection of arsenic in water. The sources of variation in results of tests for arsenic determined by GPL kit seemed to be use of different sets of apparatus, reagents and person to person handling of the apparatus. Variation in results of tests due to use of different sets of the GPL kit was more prominent (Standard deviation 76.524) than that of the reagents used and person to person handling (Standard deviation 40). Among the three sources of variation person to person handling of the kits bad the least effect on the test results. Results given by GPL and NIPSOM kits did not differ qualitatively although differed quantitatively.
format Research report
author Hossain, Md. Zabed
author_facet Hossain, Md. Zabed
author_sort Hossain, Md. Zabed
title An analytical assessment of GPL kit for field level detection of arsenic in water
title_short An analytical assessment of GPL kit for field level detection of arsenic in water
title_full An analytical assessment of GPL kit for field level detection of arsenic in water
title_fullStr An analytical assessment of GPL kit for field level detection of arsenic in water
title_full_unstemmed An analytical assessment of GPL kit for field level detection of arsenic in water
title_sort analytical assessment of gpl kit for field level detection of arsenic in water
publisher BRAC Research and Evaluation Division (RED)
publishDate 2020
url http://hdl.handle.net/10361/13415
work_keys_str_mv AT hossainmdzabed ananalyticalassessmentofgplkitforfieldleveldetectionofarsenicinwater
AT hossainmdzabed analyticalassessmentofgplkitforfieldleveldetectionofarsenicinwater
_version_ 1814307194114408448