An analytical assessment of GPL kit for field level detection of arsenic in water

An attempt was taken to evaluate the suitability of GPL kit for field level detection of arsenic in water. The sources of variation in results of tests for arsenic determined by GPL kit seemed to be use of different sets of apparatus, reagents and person to person handling of the apparatus. Varia...

Ful tanımlama

Detaylı Bibliyografya
Yazar: Hossain, Md. Zabed
Materyal Türü: Research report
Dil:English
Baskı/Yayın Bilgisi: BRAC Research and Evaluation Division (RED) 2020
Konular:
Online Erişim:http://hdl.handle.net/10361/13415
Diğer Bilgiler
Özet:An attempt was taken to evaluate the suitability of GPL kit for field level detection of arsenic in water. The sources of variation in results of tests for arsenic determined by GPL kit seemed to be use of different sets of apparatus, reagents and person to person handling of the apparatus. Variation in results of tests due to use of different sets of the GPL kit was more prominent (Standard deviation 76.524) than that of the reagents used and person to person handling (Standard deviation 40). Among the three sources of variation person to person handling of the kits bad the least effect on the test results. Results given by GPL and NIPSOM kits did not differ qualitatively although differed quantitatively.